Back to Top

1
Hi, Guest!
  • FLUKE
  • Fluke 1502A/ 1504 Thermometer Readouts

Fluke 1502A/ 1504 Thermometer Readouts

Update Terakhir
:
17 / 08 / 2020
Min. Pembelian
:
1 Unit

Harga

CALL
Karya Mandiri Instrument Indonesia adalah supplier peralatan laboratorium baik eletronik maupun mekanik, serta berbagai macam instrument measurement, dengan didukung dari berbagai macam merk dari negara negara Eropa, US, dan beberapa negara di Asia seperti Korea, Japan dan Taiwan.

Detail Fluke 1502A/ 1504 Thermometer Readouts


CALL:
A.WIHARTA
081294124885
085778084789
087784022201


Karya Mandiri Instrument indonesia
adalah supplier peralatan laboratorium baik eletronik maupun mekanik, serta berbagai macam instrument measurement, dengan didukung dari berbagai macam merk dari negara negara Eropa, US, dan beberapa negara di Asia seperti Korea, Japan dan Taiwan. Instrument yang kami sediakan seperti : Anemometer, Analitical Balance, Spectrophotometer, pHmeter, Laser survey, Micropipette, Peristaltic Pump, Flame photometer, Water bath heating cooling, Colorimeter, Water Strirer, Viscometer. Freezers, Refractometer, Polarimeter, Sound Level meter, Tachometer. Dll

Kami juga menerima jasa service dan kalibrasi untuk peralatan laboratorium sesuai kemampuan kami.

 

1502A Tweener PRT Readout The 1502A Tweener features accuracy up to ± 0.006 ° C ( the 1504 is even more accurate, up to ± 0.002 ° C) . In addition, it reads 100-ohm, 25-ohm, and 10-ohm probes, has a resolution of 0.001 ° C across its entire range, and is the smallest unit in its class. It also has an optional battery pack for completely portable operation. Each Tweener is programmable to match a probe’ s constants for maximum linearity and accuracy. All probe constants and coefficients are programmed through simple, front-panel keystrokes. Temperature is displayed in ° C, ° F, K, or resistance in ohms. The 1502A accurately measures the resistance of the probe and then converts the resistance to a temperature value using its built-in algorithms. For convenience, the 1502A reads the common industrial grade IEC-751 or “ 385 ALPHA RTD without any programming. Enter the actual R0 and ALPHA of the individual probe for increased accuracy. For maximum accuracy, use the ITS-90 formulas. The Tweener accepts the subranges 4 and 6 through 11. ITS-90 formulas reside in the Tweener’ s firmware. If your probe has been calibrated for any of the above subranges of the ITS-90, you simply enter the coefficients directly into your Tweener. Each thermometer comes complete with an RS-232 interface for automation of temperature data collection, calibrations, or process control functions. An IEEE-488 interface is available as an option. The 1502A is calibrated digitally using the front-panel buttons. You never have to open the box to calibrate it. This calibration protocol further reduces the cost of the 1502A. It goes where you go and works the way you want it to. 1504 Tweener Thermistor Readout If you need more accuracy in a limited temperature range, the Model 1504 Tweener gives it to you as a thermistor readout. Thermistors are less fragile than PRTs and less likely to be impacted by mechanical shock. Thermistors are more sensitive to temperature, have faster response times, and come in many shapes for different applications. Typical accuracy of a 1504 is ± 0.002 ° C with a resolution of 0.0001 ° C. Software With our 9934 LogWare, both Tweener models may be used for real-time data acquisition. Collect data and analyze it graphically or statistically. Additionally, Tweeners may be used as reference thermometers with our MET/ TEMP II software. Battery pack Want to take your Tweener on the road? Order Fluke Calibration' s 9320A Battery Pack. Our battery gives you 36 hours between charges, allowing you to take your work wherever you need.

Tampilkan Lebih Banyak
Kontak Kami