Back to Top

1
Hi, Guest!

Fluke 1625 Advanced Geo Earth Ground Tester

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
0 Unit

Harga

CALL
Karya Mandiri Instrument Indonesia adalah supplier peralatan laboratorium baik eletronik maupun mekanik, serta berbagai macam instrument measurement, dengan didukung dari berbagai macam merk dari negara negara Eropa, US, dan beberapa negara di Asia seperti Korea, Japan dan Taiwan.

Detail Fluke 1625 Advanced Geo Earth Ground Tester


CALL:
A.WIHARTA
081294124885
085778084789
087784022201


Karya Mandiri Instrument indonesia
adalah supplier peralatan laboratorium baik eletronik maupun mekanik, serta berbagai macam instrument measurement, dengan didukung dari berbagai macam merk dari negara negara Eropa, US, dan beberapa negara di Asia seperti Korea, Japan dan Taiwan. Instrument yang kami sediakan seperti : Anemometer, Analitical Balance, Spectrophotometer, pHmeter, Laser survey, Micropipette, Peristaltic Pump, Flame photometer, Water bath heating cooling, Colorimeter, Water Strirer, Viscometer. Freezers, Refractometer, Polarimeter, Sound Level meter, Tachometer. Dll

Kami juga menerima jasa service dan kalibrasi untuk peralatan laboratorium sesuai kemampuan kami.

 

The Fluke 1623 and 1625 are distinctive earth ground testers that can perform all four types of earth ground measurement. Specifically, the Fluke 1623 and 1625 testers are able to measure earth ground loop resistances using only clamps – called Stakeless testing. This method doesn’ t require the use of earth ground stakes or the disconnection of ground rods. Testing Methods 3- and 4-Pole Fall of Potential – standard earth ground testing using two ground stakes Selective testing – without disconnecting ground rods, a technician can measure ground resistance using a combination of stakes and a clamp. Stakeless testing – innovative solution using only clamps, instead of ground stakes, to measure earth ground loop resistance. The Fluke 1625 offers these advanced features Automatic Frequency Control ( AFC) – identifies existing interference and chooses a measurement frequency to minimize its effect, providing a more accurate earth ground value. R* measurement – calculates earth ground impedance at 55 Hz to more accurately reflect the earth ground resistance that a fault-to-earth ground would see. Adjustable limits – for quick test result verification. RA 3-pole ground resistance measurement ( IEC 1557-5) Measuring Voltage Fluke 1625 Vm = 20/ 48 V ac Short circuit current Fluke 1625 250 mA ac Measure frequency Fluke 1625 94, 105, 111, 128Hz Resolution Fluke 1625 0.001 & to 100 & Measuring range Fluke 1625 0.001 & to 299.9 k& Intrinsic error Fluke 1625 ± ( 2 % of reading + 2 d) Operating error Fluke 1625 ± ( 5 % of reading + 5 d) RA 4-pole ground resistance measurement ( IEC 1557-5) Measuring Voltage Fluke 1625 Vm = 20/ 48 V ac Short circuit current Fluke 1625 250 mA ac Measure frequency Fluke 1625 94, 105, 111, 128Hz Resolution Fluke 1625 0.001 & to 100 & Measuring range Fluke 1625 0.001 & to 299.9 k& Intrinsic error Fluke 1625 ± ( 2 % of reading + 2 d) Operating error Fluke 1625 ± ( 5 % of reading + 5 d) RA 3-pole ground resistance measurement with current clamp Measuring Voltage Fluke 1625 Vm = 20/ 48 V ac Short circuit current Fluke 1625 250 mA ac Measure frequency Fluke 1625 94, 105, 111, 128Hz Resolution Fluke 1625 0.001 & to 10 & Measuring range Fluke 1625 0.001 & to 29.99 k& Intrinsic error Fluke 1625 ± ( 7 % of reading + 2 d) Operating error Fluke 1625 ± ( 10 % of reading + 5 d) RA 4-pole selective ground resistance measurement with current clamp Measuring Voltage Fluke 1625 Vm = 20/ 48 V ac Short circuit current Fluke 1625 250 mA ac Measure frequency Fluke 1625 94, 105, 111, 128Hz Resolution Fluke 1625 0.001 & to 10 & Measuring range Fluke 1625 0.001 & to 29.99 k& Intrinsic error Fluke 1625 ± ( 7 % of reading + 2 d) Operating error Fluke 1625 ± ( 10 % of reading + 5 d) Stakeless ground loop measurement Measuring Voltage Fluke 1625 Vm = 20/ 48 V ac Measure frequency Fluke 1625 94, 105, 111, 128Hz Noise current ( Iext) Max. Iext = 2 A ( ac) ( RA < 20 & ) Fluke 1625 Max. Iext = 3 A Resolution Fluke 1625 0.001 & to 10 & Measuring range Fluke 1625 0.001 & to 29.99 k& Intrinsic error Fluke 1625 ± ( 7 % of reading + 2 d) Operating error Fluke 1625 ± ( 10 % of reading + 5 d) Environmental Specifications Working temperature -10 ° C to + 50 ° C Operating Temperature 0 ° C to + 35 ° C Nominal temperature + 18 ° C to + 28 ° C Storage Temperature Fluke 1625 -30 ° C to + 60 ° C Climatic class C1 ( IEC 654-1) , -5 ° C to + 45 ° C, 5 % to 95 % RH Protection type IP56 for case, IP40 for battery door according to EN 60529 Safety Specifications Safety Rating CAT II, 300 V

Tampilkan Lebih Banyak
Kontak Kami