Back to Top

1
Hi, Guest!
  • FLUKE
  • Fluke 732A Direct Voltage Standard

Fluke 732A Direct Voltage Standard

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
0 Unit

Harga

CALL
Karya Mandiri Instrument Indonesia adalah supplier peralatan laboratorium baik eletronik maupun mekanik, serta berbagai macam instrument measurement, dengan didukung dari berbagai macam merk dari negara negara Eropa, US, dan beberapa negara di Asia seperti Korea, Japan dan Taiwan.

Detail Fluke 732A Direct Voltage Standard


CALL:
A.WIHARTA
081294124885
085778084789
087784022201


Karya Mandiri Instrument indonesia
adalah supplier peralatan laboratorium baik eletronik maupun mekanik, serta berbagai macam instrument measurement, dengan didukung dari berbagai macam merk dari negara negara Eropa, US, dan beberapa negara di Asia seperti Korea, Japan dan Taiwan. Instrument yang kami sediakan seperti : Anemometer, Analitical Balance, Spectrophotometer, pHmeter, Laser survey, Micropipette, Peristaltic Pump, Flame photometer, Water bath heating cooling, Colorimeter, Water Strirer, Viscometer. Freezers, Refractometer, Polarimeter, Sound Level meter, Tachometer. Dll

Kami juga menerima jasa service dan kalibrasi untuk peralatan laboratorium sesuai kemampuan kami.

 

The 732B is a direct voltage standard with 10V and 1.018V outputs. The 734A is a direct voltage reference standard that consists of four 732Bs that are mechanically and electrically isolated, housed in a rack-mountable enclosure. Each standard is small, light and rugged, ideal for shipment. The long 72-hour battery life allows the 732B to be shipped over long distances under power. An optional external battery and charger extends battery life still further, to more than 130 hours. The 732B can stand up to a lot of abuse. The inputs can be shorted indefinitely and are protected up to 1100V dc, 25 mA, without damaging the cell or affecting its output. Confidence The 732B is based on the proven technology of the 732A, the first standards lab quality electronic reference to gain acceptance as a replacement for saturated standard cells. Originally designed for internal transfers of the Fluke Calibration corporate volt to the production floor, thousands are now in service world-wide in a variety of applications -- from maintaining an institutional reference to transferring values from national labs or privately-operated 10V Josephson Arrays. Stability Stability for each output is ± 2 ppm per year ( 10V) and ± 0.8 ppm per month ( 1.018V) . Each 732B can drive up to 12 mA of current to simplify use with instrumentation - like the 5700A - with low output impedance.

Tampilkan Lebih Banyak
Kontak Kami