CALL:
A.WIHARTA
081294124885
085778084789
087784022201
Karya Mandiri Instrument indonesia adalah supplier peralatan laboratorium baik eletronik maupun mekanik, serta berbagai macam instrument measurement, dengan didukung dari berbagai macam merk dari negara negara Eropa, US, dan beberapa negara di Asia seperti Korea, Japan dan Taiwan. Instrument yang kami sediakan seperti : Anemometer, Analitical Balance, Spectrophotometer, pHmeter, Laser survey, Micropipette, Peristaltic Pump, Flame photometer, Water bath heating cooling, Colorimeter, Water Strirer, Viscometer. Freezers, Refractometer, Polarimeter, Sound Level meter, Tachometer. Dll
Kami juga menerima jasa service dan kalibrasi untuk peralatan laboratorium sesuai kemampuan kami.
Basic specifications Measurement line & number of circuits Single-phase 2-wire ( 4 circuits) , single-phase 3-wire ( 2 circuits) , three-phase 3-wire ( 2 or 1 circuit) , and three-phase 4-wire ( 1 circuit) Note: 50 or 60 Hz, and that share the same voltage line Measurement item Voltage, current, active/ reactive/ apparent power, active/ reactive power integration, power factor, frequency, harmonic value Measurement range Voltage range: 150/ 300/ 600 V AC Current range: [ when using the 9694] 500 mA, 1/ 5 A AC [ when using the 9695-02] 500 mA, 1/ 5/ 10/ 50 A AC, [ when using the 9660, 9695-03] 5/ 10/ 50/ 100 A AC [ when using the 9661] 5/ 10/ 50/ 100/ 500 A AC [ when using the 9669] 100/ 500/ 1 kA AC [ when using the 9667] 500/ 5 kA AC Power range: 75 W to 9 MW ( Depends on combination of voltage and current range) Measurement method Digital sampling, PLL synchronization or 50/ 60 Hz fixed clock Basic accuracy Active power: ± 0.2% rdg. ± 0.1% f.s. + clamp-on sensor accuracy ( at 45 to 66 Hz) Display refresh rate 2 times / sec ( except when using a PC card while accessing the internal memory, or when performing RS-232C communications) Data save interval Standard interval: 1/ 2/ 5/ 10/ 15/ 30 seconds, or 1/ 2/ 5/ 10/ 15/ 30/ 60 minutes Frequency characterristics Fundamental waveforms up to the 50th order ± 3% f.s. + measurement accuracy ( of a 45- to 66-Hz fundamental waveform) Other functions Error connect check, language selection, display hold, setting backup, power shut off management, key lock, [ 3169-21 only] D/ A output 4 channels, ± 5 V DC f.s.) Power requirements 100 to 240 V AC, 50/ 60 Hz, 30 VA max. Dimensions, mass 210 mm ( 8.27 in) W × 160 mm ( 6.30 in) H × 60 mm ( 2.36 in) D, 1.2 kg ( 42.3 oz) Supplied accessories Voltage cord set 9438-53 × 1 ( 1 cord each of black, red, yellow, and blue) , Power cord × 1, Instruction manual × 1, Quick start manual × 1, CD-R × 1 ( RS-232C interface operating manuals) , Input cord label × 1, Connection cable 9441 × 1 ( for the 3169-21 only)