CALL:
A.WIHARTA
081294124885
085778084789
087784022201
Karya Mandiri Instrument indonesia adalah supplier peralatan laboratorium baik eletronik maupun mekanik, serta berbagai macam instrument measurement, dengan didukung dari berbagai macam merk dari negara negara Eropa, US, dan beberapa negara di Asia seperti Korea, Japan dan Taiwan. Instrument yang kami sediakan seperti : Anemometer, Analitical Balance, Spectrophotometer, pHmeter, Laser survey, Micropipette, Peristaltic Pump, Flame photometer, Water bath heating cooling, Colorimeter, Water Strirer, Viscometer. Freezers, Refractometer, Polarimeter, Sound Level meter, Tachometer. Dll
Kami juga menerima jasa service dan kalibrasi untuk peralatan laboratorium sesuai kemampuan kami.
Basic Specifications Power quality measurement standard compliance IEEE 1159, IEC 61000-4-30 Ed. 2 Class A Maximum recording period 1 month ( with repeat function on: 55 weeks) Maximum number of recordable events 1, 000 ( with repeat function on: 55, 000) Interfaces SD card slot ( for writing data to an SD memory card) , LAN ( for remote operation and downloading of recorded data) , USB ( for downloading of recorded data) , RS-232C ( for printer and GPS connectivity) Power supply Rated supply voltage: 12 V DC ( maximum rated power: 35 VA) AC ADAPTER Z1002, BATTERY PACK Z1003 Continuous battery-powered operating time Approx. 180 min. ( with BATTERY PACK Z1003) Dimensions Approx. 300 ( W) × 211 ( H) × 68 ( D) mm ( excluding protruding parts) Weight Approx. 2.57 kg ( including BATTERY PACK Z1003) Measurement Specifications 1. Time Plot Voltage items RMS voltage, waveform peak, harmonic, harmonic phase angle, inter-harmonics, high-order harmonic component, total harmonic distortion factor, unbalance factor ( negative-phase and zero-phase) , DC voltage, frequency ” V10 Current items RMS current, waveform peak, harmonic, harmonic phase angle, inter-harmonics, high-order harmonic component, total harmonic distortion factor, unbalance factor ( negative-phase and zero-phase) , DC current, K factor Power items Active power, reactive power, apparent power, harmonic power, harmonic voltage-current phase difference, active integral power, reactive integral power, power factor 2. Event acquisition Transients, swells, dips, interruptions, frequency, rush current, voltage waveform comparison, timer, external, and other combinations of the time series item events listed above Input Specifications Measurement line 1-phase 2-wire, 1-phase 3-wire, 3-phase 3-wire, 3-phase 4-wire Plus 1 channel in addition to the above measurement lines Measurement frequency Basic frequency: 50/ 60/ 400 Hz Transient overvoltage: 2 MHz sampling Harmonic measurement Orders 0 ( DC) to 50 ( 2.5 kHz or 3 kHz) Voltage measurement range Voltage measurement: 600.00 Vrm Transient overvoltage measurement: ± 6.0000 kV peak Current measurement range Load current measurement With 9694 sensor: 5.0000/ 50.000 Arms With 9660 sensor: 50.000/ 100.00 Arms With 9661 sensor: 50.000/ 500.00 Arms With 9667 sensor: 50.000/ 500.00 A, 500.00 A/ 5.0000 kArms With 9669 sensor: 100.00 A/ 1.0000 kArms Leak current measurement With 9675/ 9657-10 sensor: 500.00 mA/ 5.0000 Arms Measurement accuracy ( 50 Hz/ 60 Hz measurement) RMS voltage ± 0.1% rdg. RMS current ± 0.2% rdg. ± 0.1% f.s. + current sensor accuracy Active power ± 0.2% rdg. ± 0.1% f.s. + current sensor accuracy