Back to Top

1
Hi, Guest!
  • alat uku Hanna HI 9147 Dissolved Oxygen Meter for Aquaculture

Alat Uku Hanna HI 9147 Dissolved Oxygen Meter For Aquaculture

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
1 Unit

Harga

CALL
Karya Mandiri Instrument Indonesia adalah supplier peralatan laboratorium baik eletronik maupun mekanik, serta berbagai macam instrument measurement, dengan didukung dari berbagai macam merk dari negara negara Eropa, US, dan beberapa negara di Asia seperti Korea, Japan dan Taiwan.

Detail Alat Uku Hanna HI 9147 Dissolved Oxygen Meter For Aquaculture

CALL:

A.WIHARTA

081294124885

085778084789

087784022201

 

Info Produk

Designed specifically for aquaculture
Galvanic DO probe
Backlit LCD
Automatic Temperature Compensation
Manual salinity and altitude compensation
Water-resistant

HI 9147 is designed for aquaculture applications. This unit is unique among our family of DO meters as it is supplied with a galvanic probe.

Unlike polarographic probes, galvanic DO probes require no conditioning time. When you need to measure multiple samples in a given period of time, pick it up and measure on demand.

HI 9147 is a must have for DO sensitive organisms or high bio-load environments.

Order Information:
HI 9147-04 is supplied with HI 76409/ 4 probe with 4 m ( 13’ ) cable and spare membranes ( 2) , electrolyte solution ( 30 mL) , batteries, screwdriver and instructions.
HI 9147-10 is supplied with HI 76409/ 10 probe with 10 m ( 32.8’ ) cable and spare membranes ( 5) , electrolyte solution ( 30 mL) , batteries, screwdriver and instructions.
HI 9147-15 is supplied with HI 76409/ 15 probe with 15 m ( 49.2’ ) cable and spare membranes ( 5) , electrolyte solution ( 30 mL) , batteries, screwdriver and instructions.
HI 9147-20 is supplied with HI 76409/ 20 probe with 20 m ( 65.6’ ) cable and spare membranes ( 5) , electrolyte solution ( 30 mL) , batteries, screwdriver and instructions.

Range O2 0.0 to 50.0 mg/ L ( ppm)
% Saturation O2 0 to 600 %
Temperature -5.0 to 50.0° C ( 32.0 to 122.0º F)
Resolution O2 0.1 mg/ L ( ppm) or 1%
Temperature 0.1° C ( 1º F)
Accuracy ( @ 20° C) O2 ± 1% of reading
Temperature ± 0.2° C ( 1º F) ( excluding probe error)
Calibration manual, in saturated air
Temperature
Compensation automatic, -5 to 50° C ( 23° F to 122° F)
Salinity
Compensation 0 to 4000 m ( resolution 100 m)
Salinity
Compensation 0 to 51 g/ L ( ppt) ( 1 g/ L resolution)
Battery Type /
Life 1.5V AAA ( 3) / approx. 1, 000 hours of continuous use without backlight
Environment 0 to 50° C ( 32 to 122° F) ; RH max 95% non-condensing
Dimensions 185 x 72 x 36 mm ( 7.3 x 2.8 x 1.4” )
Weight 450 g ( 15.9 oz.)
Tampilkan Lebih Banyak