Back to Top

1
Hi, Guest!

Alat Ukur Listrik,Agen Fluke 1735 Three Phase Power Logger

Update Terakhir
:
12 / 11 / 2023
Min. Pembelian
:
1 Unit

Harga

CALL
Karya Mandiri Instrument Indonesia adalah supplier peralatan laboratorium baik eletronik maupun mekanik, serta berbagai macam instrument measurement, dengan didukung dari berbagai macam merk dari negara negara Eropa, US, dan beberapa negara di Asia seperti Korea, Japan dan Taiwan.

Detail Alat Ukur Listrik,Agen Fluke 1735 Three Phase Power Logger

perlengkapan listrik lainnya

Info Produk

Record power and associated parameters for up to 45 days Monitor maximum power demand over user defined averaging periods Prove the benefit of efficiency improvements with energy consumption tests Measure harmonic distortion caused by electronic loads Improve reliability by capturing voltage dips and swells from load switching Easily confirm instrument setup with color display of waveforms and trends Measure all three phases and neutral with included 4 flexible current probes View graphs and generate reports with included Power Log software Compact rugged design with IP65 case 600 V CAT III and two year warranty Specifications General Display VGA Graphic Color transmissive displays 320 x 240 Pixel with additional background lighting and adjustable contrast text and graphics in color Quality Developed designed and manufactured according to DIN ISO 9001 Memory 4 MB Flash memory 3.5 MB for measuring data Interface RS 232 SUB D socket 115.2 k Baud 8 data bits no parity 1 stop bit firmware updates are possible with the RS 232 interface 9 pole extension cable Sample rate 10.24 kHz Line frequency 50 Hz or 60 Hz user selectable with automatic synchronization Power supply NiMH battery pack with ac adapter 15 V to 20 V 0.8 A Operation time with battery Typical 12 hours without backlight and 6 hours with backlight high Dimensions 240 mm x 180 mm x 110 mm Weight 1.7 kg including battery Ambient conditions Working temperature range 10 C to 50 C Storage temperature range 20 C to 60 C Operating temperature range 0 C to 40 C Reference temperature range 23 C 2 C Note The above terms are defined in European Standards. To calculate the specification at any point in the working temperature range use the temperature coefficient below. Temperature coefficient 0.1 of the measured value per C from the reference Intrinsic error Refers to reference temperature maximum deviation is guaranteed for two years Operating error Refers to operating temperature range maximum deviation is guaranteed for two years Climatic class C1 IEC 654 1 5 C to 45 C 5 to 95 RH no dew Housing Cycoloy shock and scratch proof thermoplast V0 type non flammable with rubber protection holster EMC Emission IEC EN 61326 1 1997 class B Immunity IEC EN 61326 1 1997 Safety Safety IEC 61010 1 600 V CAT III double or reinforced insulation pollution degree 2 Protection IP65 EN60529 refers only to the main housing without the battery compartment RMS values are measured with a 20 ms resolution. V rms wye measurement Measuring range 57 V 66 V 110 V 120 V 127 V 220 V 230 V 240 V 260 V 277 V 347 V 380 V 400 V 417 V 480 V ac Intrinsic error 0.2 of measured value 5 digits Operating error 0.5 of m. v. 10 digit Resolution 0.1 V V rms delta measurement Measuring range 100 V 115 V 190 V 208 V 220 V 380 V 400 V 415 V 450 V 480 V 600 V 660 V 690 V 720 V 830 V ac Intrinsic error 0.2 of m. v. 5 digit Operating error 0.5 of m. v. 10 digit Resolution 0.1 V A rms measurement Flexi set I ranges 15 A 150 A 3000 A rms at sine Current clamp ranges 1 A 10 A Resolution 0.01 A Ranges 150 A 3000 A and 1 A 10 A Intrinsic error 0.5 of m. v. 10 digit Operating error 1 of m. v. 10 digit Ranges 15 A Intrinsic error 0.5 of m. v. 20 digit Operating error 1 of m. v. 20 digit The errors of the current probes are not considered. By using Flexi Set Flexi Set measuring error 2 of m. v. 10 digit Position influence 3 of m. v. 10 digit CF typical 2.83 Note When using Flexi Set please make sure to position the conductor opposite to the Flexi Set lock Power measurement P Active S Apparent Q reactive D Distorting Measuring range see V rms and A rms measurement Power errors are calculated by adding the errors of voltage and current Additional error due to power factor PF Specified error x 1 PF Maximum range with voltage range 830 V delta connection and 3000 A current range is 2.490 MW higher displayed values possible when using PTs and CTs with ratio feature Intrinsic error 0.7 of m.v. 15 digit Resolution 1 kW Operating error 1.5 of m.v. 20 digit Typical range with voltage range 230 V wye connection and 150 A current range is 34.50 KW. Intrinsic error 0.7 of m.v. 15 digit Resolution 1 W to 10 W Operating error 1.5 of m.v. 20 digit The errors of the current sensors themselves have not
Tampilkan Lebih Banyak
Kontak Kami