Back to Top

1
Hi, Guest!

Socorex Manual Multichannel Micropipettes Cat 855.12.350

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
0 Unit

Harga

CALL
Karya Mandiri Instrument Indonesia adalah supplier peralatan laboratorium baik eletronik maupun mekanik, serta berbagai macam instrument measurement, dengan didukung dari berbagai macam merk dari negara negara Eropa, US, dan beberapa negara di Asia seperti Korea, Japan dan Taiwan.

Detail Socorex Manual Multichannel Micropipettes Cat 855.12.350


CALL:
A.WIHARTA
081294124885
085778084789
087784022201


Karya Mandiri Instrument indonesia
adalah supplier peralatan laboratorium baik eletronik maupun mekanik, serta berbagai macam instrument measurement, dengan didukung dari berbagai macam merk dari negara negara Eropa, US, dan beberapa negara di Asia seperti Korea, Japan dan Taiwan. Instrument yang kami sediakan seperti : Anemometer, Analitical Balance, Spectrophotometer, pHmeter, Laser survey, Micropipette, Peristaltic Pump, Flame photometer, Water bath heating cooling, Colorimeter, Water Strirer, Viscometer. Freezers, Refractometer, Polarimeter, Sound Level meter, Tachometer. Dll

Kami juga menerima jasa service dan kalibrasi untuk peralatan laboratorium sesuai kemampuan kami.

 

Equipped with a precision setting mechanism, the line is continuously adjustable down to a very fine volume resolution. Single-handed volume setting easy when other hand busy. Click stops, together with freely rotating Smartie plunger button cap secure setting stability while pipetting. These multichannel instruments extend pipetting possibilities in microplates. The line offers 8- and 12-channel models with volumes ranging from 0.5 to 350 µ L. Ordering and performance information 8-channel models Inaccuracy ( Rel. err.% ) Imprecision ( CV % ) Cat. No. Vol. µ L Div. µ L Min. vol. Mid. vol. Max. vol. Min. vol. Mid. vol. Max. vol. Tip style 855.08.010 0.5 - 10 0.01 < ± 3.5% * < ± 2.5% < ± 1.5% < 3.0% < 2.0% < 1.0% 10 µ L 855.08.050 5 - 50 0.1 < ± 1.0% < ± 0.9% < ± 0.8% < 1.0% < 0.7% < 0.4% 200 µ L 855.08.200 20 - 200 0.2 < ± 0.9% < ± 0.8% < ± 0.7% < 0.6% < 0.5% < 0.3% 200 µ L 855.08.350 40 - 350 0.4 < ± 1.0% < ± 0.9% < ± 0.8% < 0.6% < 0.5% < 0.3% 350 µ L 12-channel models Inaccuracy ( Rel. err.% ) Imprecision ( CV % ) Cat. No. Vol. µ L Div. µ L Min. vol. Mid. vol. Max. vol. Min. vol. Mid. vol. Max. vol. Tip style 855.12.010 0.5 - 10 0.01 < ± 3.5% * < ± 2.5% < ± 1.5% < 3.0% < 2.0% < 1.0% 10 µ L 855.12.050 5 - 50 0.1 < ± 1.0% < ± 0.9% < ± 0.8% < 1.0% < 0.7% < 0.4% 200 µ L 855.12.200 20 - 200 0.2 < ± 0.9% < ± 0.8% < ± 0.7% < 0.6% < 0.5% < 0.3% 200 µ L 855.12.350 40 - 350 0.4 < ± 1.0% < ± 0.9% < ± 0.8% < 0.6% < 0.5% < 0.3% 350 µ

Tampilkan Lebih Banyak
Kontak Kami